# New ports collection makefile for: apcupsd
# Date created: 1.12.2001
# Whom: Lars Köller <Lars.Koeller@Uni-Bielefeld.DE>
#
# $FreeBSD: ports/sysutils/apcupsd/Makefile,v 1.53 2007/10/21 10:39:38 itetcu Exp $
#
PORTNAME= apcupsd
PORTVERSION= 3.14.2
CATEGORIES= sysutils
MASTER_SITES= ${MASTER_SITE_SOURCEFORGE:S/$/:src_sf/g} \
http://sce-tindy.tecnik93.com/FreeBSD/ports/${PORTNAME}/sources/:src_bk \
http://apcupsd.sourceforge.net/manual/:doc_sf \
http://sce-tindy.tecnik93.com/FreeBSD/ports/${PORTNAME}/sources/:doc_bk
MASTER_SITE_SUBDIR= ${PORTNAME}/:src_sf
DISTFILES= ${DISTNAME}${EXTRACT_SUFX}:src_sf,src_bk \
${PORTNAME}.pdf:doc_sf,doc_bk
EXTRACT_ONLY= ${DISTNAME}${EXTRACT_SUFX}
IGNOREFILES= ${PORTNAME}.pdf
MAINTAINER= itetcu@FreeBSD.org
COMMENT= A daemon for controlling APC UPS
BUILD_DEPENDS= makedepend:${PORTSDIR}/devel/makedepend
USE_RC_SUBR= apcupsd
SUB_FILES= pkg-message
GNU_CONFIGURE= yes
CONFIGURE_ARGS= --sbindir=${PREFIX}/sbin \
--with-nologin=/var/run \
--disable-install-distdir \
--sysconfdir=${ETCDIR} \
--with-serial-dev=/dev/usv
CONFIGURE_ENV= CPPFLAGS="-I${LOCALBASE}/include -L${LOCALBASE}/lib" \
CFLAGS="-I${LOCALBASE}/include -L${LOCALBASE}/lib" \
LDFLAGS="-L${LOCALBASE}/lib"
MAN8= apcupsd.8
OPTIONS= CLIENT_ONLY "Build NIS client only (no network server)" off \
CGI "Compile with CGI programms to show status" off \
USB "Compile with USB Support (READ MANUAL!)" on \
SNMP "Compile with SNMP Support (READ MANUAL!)" on
PORTDOCS= ${PORTNAME}.pdf
.include <bsd.port.pre.mk>
.if defined(WITH_CLIENT_ONLY)
CONFIGURE_ARGS+= --enable-net
.endif
.if defined(WITH_CGI)
CONFIGURE_ARGS+= --enable-cgi --with-cgi-bin=${ETCDIR}/cgi
LIB_DEPENDS+= gd.4:${PORTSDIR}/graphics/gd
PLIST_SUB+= CGI=""
.else
PLIST_SUB+= CGI="@comment "
.endif
.if !defined(WITHOUT_USB)
CONFIGURE_ARGS+= --enable-usb
.endif
.if !defined(WITHOUT_SNMP)
LIB_DEPENDS+= netsnmp.10:${PORTSDIR}/net-mgmt/net-snmp
CONFIGURE_ARGS+= --enable-snmp
.endif
CONFIGURE_ARGS+= --enable-powerflute --with-libwrap=yes
CONFIGURE_ENV+= LIBS="-lcurses -lmenu"
PLIST_SUB+= POWERFL=""
post-configure:
@${REINPLACE_CMD} -e "s|%PREFIX%|${PREFIX}|g" ${WRKSRC}/doc/apcupsd.man
post-install:
# If the files presaved are identical with the new one, include then in
# the package list. So the port could be removed without problems
for na in apccontrol commfailure mainsback mastertimeout \
changeme commok masterconnect onbattery; do \
if [ -f ${ETCDIR}/$$na.orig ]; then \
if cmp -s ${ETCDIR}/$$na ${ETCDIR}/$$na.orig; then \
${ECHO_CMD} "%%ETCDIR%%/$$na.orig" >> ${TMPPLIST}; \
fi \
fi; \
done
@${ECHO_CMD} "@unexec if [ -d %D/${ETCDIR_REL} ]; then ${ECHO_CMD} \"If you are permanently removing this port, you should do a ``rm -rf ${ETCDIR}`` to remove config files left.\" | ${FMT} ; fi" >> ${TMPPLIST}
# Install sample startup script
# If there is already a config file it is installed as ...new
for na in apcupsd.conf apcupsd.css hosts.conf multimon.conf; do \
if [ -f ${ETCDIR}/$$na ]; then \
if [ -f ${ETCDIR}/$$na.new ]; then \
${MV} ${ETCDIR}/$$na.new ${ETCDIR}/$$na.sample; \
else \
${CP} ${ETCDIR}/$$na ${ETCDIR}/$$na.sample; \
fi; \
fi; \
done
.if !defined(NOPORTDOCS)
@${MKDIR} ${DOCSDIR}
cd ${DISTDIR} && ${INSTALL_DATA} ${PORTNAME}.pdf ${DOCSDIR}
.endif
@${CAT} ${PKGMESSAGE}
.include <bsd.port.post.mk>